Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
GBR with an e-PTFE membrane associated with DFDBA: Histologic and histochemical analysis in a human implant retrieved after 4 years of loading
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 16 , Issue 4
July/August 1996

Pages 339-348


GBR with an e-PTFE membrane associated with DFDBA: Histologic and histochemical analysis in a human implant retrieved after 4 years of loading

Simion/Trisi/Piattelli


PMID: 9242101
DOI: 10.11607/prd.00.0181

As a result of a fracture to the cemented post and core, a pure titanium implant was extracted from a 54-year-old patient after 4 years of clinical loading. At implantation, the implant was positioned into an extraction socket and the defect was treated with an e-PTFE membrane associated with a DFDBA graft. At retrieval the implant underwent histologic and histochemical examination to assess the characteristics of the regenerated bone after 4 years of prosthetic loading. The implant showed an angular bony defect at the smooth collar, but the bone-implant dierct contact rate seemed to be elevated in the remaining implant surface. Normal transmitted and polarized light examinations demonstrated that most of the DFDBA particles were resorbed and substituted by vital newly formed bone. The regenerated bone appeared compact with secondary osteons and large haversian canals; however, some partially mineralized remnants residuated in the spaces between the osteons. Within the limits of this study, the authors concluded that DFDBA can be substituted by the host bone, but the rate of substitution is very slow and not complete after 4 years. From a clinical point of view, however, the load-bearing capacity of the bone regenerated with the membrane technique associated with DFDBA appeared to be similar to that of normal bone.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help